Skip to content

Events, documents and addresses

This page is the reference for what a script uses to reach the engine: the event evt every function receives, the document object xdb, element objects, the XML DOM of new XML(..), thread objects, the address language that GetValue and SetValue take, the address functions (count, json, api. …), the # command addresses, and the sta word with its STA functions. The ideas behind it are in Timers and events and Scripting; read those first. Every result below was measured on engine 4.4.2.702.


The sample document

The examples on this page read this root document and a second document PLANT/S00. Their results are written as comments.

<xdb id="XDB" tid="S01" sta="0x0300" xdb_start="main.start(evt);" ...>
  <config>
    <script id="main" xdb_fnc="[SCR.prs]" src="%DB%/main.js" sta="0x0303" sta_typ="0x142"></script>
    <script id="api"  xdb_fnc="[SCR.prs]" src="%DB%/api.js"  sta="0x0303" sta_typ="0x142"></script>
    <doc id="PLANT/S00" sta="0x0300" src="%DB%/db_PLANT.xml"/>
    <cls id="cls_PRESS" val_typ="0x1308" val_unt="bar"/>
  </config>
  <data>
    <thr id="TH_MAIN" xdb_fnc="[THR.cre]" thr_per="50" thr_wrk="1" sta="0x0303" sta_typ="0x142" sta_fnc="[THR.sta]"/>
    <var id="POWER" val="0" val_typ="0x1308" val_unt="kW" val_fnc="[main.on_power]" sta="0x0303" sta_typ="0x142"/>
    <var id="SPEED" val="0" val_typ="0x0308" sta="0x0303" sta_typ="0x142"/>
    <var id="COUNT" val="5" val_typ="0x1204" sta="0x0303" sta_typ="0x142"/>
    <var id="FLAGS" val="0x0010" val_typ="0x0142" sta="0x0303" sta_typ="0x142"/>
    <var id="NOTE"  val="abc" sta="0x0303" sta_typ="0x142"/>
    <var id="PRESS" xdb_cls="cls_PRESS" val="2" sta="0x0303" sta_typ="0x142"/>
    <list id="TANKS" sta="0x0303" sta_typ="0x142">
      <item id="T1" val="10"   val_typ="0x0308" sta="0x0303" name="one"/>
      <item id="T2" val="20.5" val_typ="0x0308" sta="0x0303" name="two"/>
      <item id="T3" val="-3"   val_typ="0x0308" sta="0x0303" name="three"/>
      <item         val="7"    val_typ="0x0308" sta="0x0303" name="spare"/>
    </list>
    <list id="NEW_ROWS" sta="0x0303" sta_typ="0x142"/>
  </data>
</xdb>

PLANT/S00 holds <var id="LEVEL" val="42.5" val_typ="0x1308" .../> and three more <var>s under its <data>.


evt: the event

Every function the engine calls gets one argument, evt: a chain function (val_fnc="[main.f]"), a life-cycle hook (xdb_start="main.start(evt);"), a ForEach handler, a server page, a protocol hook. It says what is happening (which element, which attribute, the new and the old value, who caused it) and it is the handle every read and write goes through.

Field Holds Write
evt.doc The id of the document the event runs in ("XDB") no
evt.id The id of the element the event is on; "" when it has none no
evt.atr The attribute being written: val, sta, evt, pro, … "" in xdb_start and in a queued script no
evt.flg Flags: where the write came from, its direction — below yes
evt.user_role Who caused it: 0–7 a user's role, 8 a document, 9 the engine itself no
evt.cnt How deep in chains: 0 in xdb_start, 1 in a chain a script's write started, one more per chain a chain starts. Above 100 the chain is not run (PANIC ... nested call limit) no
evt.obj The element the event is on, as an element object. evt.elm is the same no
evt.cls The element named in the element's xdb_cls, as an element object; undefined without one no
evt.val_typ The type code of evt.valn, as hex (0x0308) no
evt.valn The value being written. evt.val is the same yes
evt.valp The value stored before this write yes
evt.stan The element's sta as it will be after this event yes
evt.stap The element's sta before it yes
evt.thr The thread the event runs on: the document (XDB_DOC), a <thr> (XDB_THR) or a connection no
evt.ses The connection session the event came through (a page's visitor, a server connection); undefined otherwise no
evt.src The event that caused this one no
evt.src_doc, evt.src_id, evt.src_atr doc, id and atr of evt.src no

What the fields hold depends on who called. Measured: POWER written from xdb_start, a timer on TH_MAIN, a GPIO <bi> polled on a simulated connection CN_G, a server page:

xdb_start val_fnc sta_fnc evt_fnc (timer) pro_fnc (device) ForEach handler page
evt.atr "" val sta evt pro sta, or the attribute named pro
evt.valn undefined the value written the new sta 1 the device's value the attribute's value —
evt.valp undefined the stored value the old sta 0 the stored value the same —
evt.flg 0x0300 the writer's source + 0x0800 (0x0B00 from xdb_start); 0x0100 through an element object 0x8B00 0x0207 0x0140 0x8900 0x0140
evt.thr.id XDB the writer's thread the writer's thread TH_MAIN CN_G XDB the HTTP <con>
evt.user_role 9 9 9 9 9 the caller's the visitor's (0 before login)

sta_fnc, pro_fnc and val_fnc run as the engine (role 9) whoever wrote: they are the engine's own cascade, which writes across elements. Every other <atr>_fnc (opr_fnc, qry_fnc, …) runs with the writer's role. Measured from a page with a Guest visitor: val_fnc saw 9, opr_fnc saw 0.

Inside a chain

The chain runs before the value is stored. In a val_fnc, evt.obj.val is still the old value and evt.valn the new one:

function on_power(evt)
{
    evt.Log(4, evt.valn + " over " + evt.obj.val);   // "7.5 over 0" for a write of 7.5
    return 0;
}

What a chain function returns is ignored. Measured, a val_fnc returning 1 or 99 changed nothing: the value was stored. A chain function changes the outcome through the event:

To Write Measured
store another value evt.valn = 100; a write of 500 stored 100
keep the old value evt.valn = evt.valp; a write of 5000 left 10; nothing is stored or published
store nothing set bit 0x2000 of evt.flg (below) a write of -5 left 10
change the element's sta evt.stan = STA.set_run_alm(evt.stan, STA.ALARM); sta 0x0303 became 0x030B when the event ended
function guard(evt)            // val_fnc
{
    if (evt.valn < 0) evt.flg = evt.flg | 0x2000;   // not stored, not published
    return 0;
}

A change of evt.stan is applied as a write of sta when the event ends, so the element's sta_fnc runs then. STA.upd applies it at once, in the middle of the chain. The functions after yours in the chain see what you wrote into evt.valn.

In a sta_fnc the new sta is evt.valn and the old one evt.valp. evt.stan may already show the new one or not, depending on how sta was written: read evt.valn.

evt.GetValue

evt.GetValue(adr) → the value, or undefined

Reads one attribute. adr is an address ending in /@attribute, or an address function.

Argument Meaning
adr Text. "id('POWER')/@val", "count(id('TANKS')/item)", "doc('PLANT/S00')/id('LEVEL')/@val"

Returns the attribute's value with its own type: a number for a 0x0308, hex for a 0x0142, text for an untyped attribute. When the address matches several elements, the first one's. A missing element, an address with no @attribute, an unknown document or a read the role may not make gives undefined. A missing attribute of an element that exists gives "", not undefined.

evt.GetValue("id('POWER')/@val")          // 0
evt.GetValue("id('POWER')/@val_unt")      // "kW"
evt.GetValue("id('FLAGS')/@val")          // 0x0010
evt.GetValue("id('PRESS')/@val_unt")      // "bar": from its class
evt.GetValue("id('TANKS')/item/@name")    // "one": the first of four
evt.GetValue("id('POWER')/@nope")         // "": the element exists
evt.GetValue("id('NOPE')/@val")           // undefined
evt.GetValue("id('POWER')")               // undefined: no attribute named

Test a read that may be missing with !x, which catches both: x == null is false for the "" of a missing attribute.

evt.SetValue

evt.SetValue(adr, value) → 1 or 0

Writes value into the attribute: it is converted to the attribute's type, the attribute's chain runs (when its type has a run bit), it is stored and published. When the address matches several elements, every one is written.

Argument Meaning
adr An address ending in /@attribute, a # command, or an api. call
value Any value. An object or array is stored as its JSON text

Returns 0 when the role may not write (xdb_acl; one ALERT line), when the document is unknown, or when the argument count is wrong. Everything else returns 1 — also an address that matched nothing. It is not an existence test.

evt.SetValue("id('SPEED')/@val", 1.23456)    // 1, SPEED = 1.23456
evt.SetValue("id('POWER')/@val", "8.25")      // 1, POWER = 8.25: text is converted
evt.SetValue("id('POWER')/@val", "abc")       // 1, POWER = 0, no line in the log
evt.SetValue("id('NOPE')/@val", 1)            // 1: nothing was written
evt.SetValue("id('SPEED')/@newatr", 5)        // 1, creates newatr = "5" (text)
evt.SetValue("id('TANKS')/item/@tag", "x")    // 1, all four items get tag="x"
evt.SetValue("id('NOTE')/@val", { "a": 1 })   // 1, NOTE = '{"a":1}'
evt.SetValue("doc('NOPE')/id('X')/@val", 2)   // 0

Three traps:

  • An attribute that does not exist is created, as text. A typing error in the name creates a new attribute and leaves the real one alone, silently.
  • A local attribute (type 0x4xxx) written from another document is not stored: its chain runs, the call returns 1, and one WARN line (then one every 10 minutes) says value not stored -- the attribute is LOCAL (0x4000) and the write came from another document. From inside its own document it is written.
  • A write made from xdb_init or xdb_start — or from work queued there — carries the update flag (EVT.FLG_SRC_UPD), and PRO.out does not send an update to the device: measured, a GPIO output written from xdb_start stored 1 and the pin stayed low; the same write from a timer's evt_fnc drove it. Write device outputs from a timer or an event, not from the start hook.

evt.MskValue

evt.MskValue(adr, value, mask) → 1 or 0

Writes old & mask | value: the bits in mask are kept, then value is OR-ed in. For integer and hex attributes; on a float the result means nothing (measured 10.73 → 1 for MskValue(.., 1, 0)). Returns as SetValue.

// FLAGS = 0x00F0
evt.MskValue("id('FLAGS')/@val", 0x0003, 0xFF0F)   // FLAGS = 0x0003

On sta the engine derives the run state from the command: MskValue("id('X')/@sta", 0x0100, 0xF0FF) on a running 0x0303 gives 0x0101, not 0x0103.

evt.XorValue

evt.XorValue(adr, value) → 1 or 0

Writes old ^ value, bit by bit. For integer and hex attributes.

// FLAGS = 0x0003
evt.XorValue("id('FLAGS')/@val", 0x0101)   // FLAGS = 0x0102

evt.AddValue

evt.AddValue(adr, value) → 1 or 0

Writes old + value, in one step, under the attribute's own type.

evt.AddValue("id('SPEED')/@val", 10)     // 1.23456 -> 11.23456
evt.AddValue("id('SPEED')/@val", -0.5)   // -> 10.73456

evt.AskValue

evt.AskValue(adr, prm) → the answer

The write that answers. Its use is with #JScript and with functions:

adr What happens Returns
"#JScript" prm is script text, evaluated here the value of the last expression
"doc('X')/#JScript" the same, in document X: xdb, evt.obj and the modules are X's the same
"api.f(a, b)" api.f is called with prm as its last argument (api) the function's answer
"#shell" a console command (help, ver, log 4 20) its text; 0 for an unknown one
a value address written, as SetValue undefined
evt.AskValue("#JScript", "1+2")                          // 3
evt.AskValue("#JScript", "var a=5; a*2")                 // 10
evt.AskValue("api.plain()", "hello")                     // "plain:hello:0"
evt.AskValue("doc('PLANT/S00')/#JScript", "xdb.id")      // "PLANT/S00"
evt.AskValue("#shell", "ver")                            // "platform : 4.4.2 build 702 ..."

#JScript runs with the caller's role.

evt.QueValue

evt.QueValue(adr, value, pri, delay, syn, thr) → 1 or 0

Does it later, or on another thread: a write, a script, or a function call goes into a thread's queue. Only the first two arguments are required.

Argument Meaning
adr A value address ("id('X')/@val"), "#JScript", "#PyScript", or an api. call ("api.f(1)")
value The value to write; the script text for #JScript / #PyScript; for an api. call, its last argument
pri How a second entry with the same identity merges, THR.QUEADD_* below. Default THR.QUEADD_MULTI
delay Milliseconds to wait. Default 0
syn For QUEADD_LOOP: align the repeats to a wall-clock boundary of this many ms. Default 0
thr The thread: a <thr> or <con> id, "/" for the document's own thread. Default: the caller's thread. "TH_MAIN/@LABEL", "/@LABEL", "@LABEL" add a label to a script or call
pri Value A second entry with the same identity
THR.QUEADD_MULTI 2 is queued too: both run
THR.QUEADD_LAST 3 replaces the first: new value, new time
THR.QUEADD_FIRST 4 is dropped: old value, old time
THR.QUEADD_VALUE 5 new value, old time
THR.QUEADD_TIME 6 old value, new time
THR.QUEADD_LOOP 7 the entry repeats every delay ms until deleted
+ THR.QUEADD_DELETE 0x20 nothing is queued: the waiting entry is deleted

The identity of an entry is its priority, the element and the attribute. A script or a call has no attribute, so two of them from the same element are one entry: give each a label in thr. Measured, all queued to TH_MAIN at the same instant:

evt.QueValue("id('SPEED')/@val", 11, THR.QUEADD_LAST, 300, 0, "TH_MAIN");
evt.QueValue("id('SPEED')/@val", 12, THR.QUEADD_LAST, 300, 0, "TH_MAIN");   // SPEED = 12 at 300 ms
evt.QueValue("id('COUNT')/@val", 40, THR.QUEADD_TIME, 500, 0, "TH_MAIN");
evt.QueValue("id('COUNT')/@val", 41, THR.QUEADD_TIME, 100, 0, "TH_MAIN");   // COUNT = 40 at 100 ms

evt.QueValue("#JScript", "main.scan(evt)", THR.QUEADD_LOOP, 300, 0, "TH_MAIN/@SCAN"); // at 300, 600, 900 ms ...
evt.QueValue("#JScript", "", THR.QUEADD_LOOP | THR.QUEADD_DELETE, 0, 0, "TH_MAIN/@SCAN"); // stopped

In a queued script evt.obj is the element that queued it and evt.thr the thread it runs on; with a label, evt.id is the thread's id and evt.atr the label (else ""). To run a function of another module later, queue #JScript with the call as text: a call form such as "main.f(evt)" in adr is accepted (1) and never runs (measured).

1 means accepted, not done. A thread name that matches nothing returns 1 and drops the work with one ERROR line (queued work names thread 'X', which is no <thr> or <con> of this document -- DROPPED); #PyScript with no Python script loaded returns 1 with an ALERT line. A value write the role may not make is not queued and returns 0. Queued work runs only after the function that queued it returns, when the target is its own thread.

evt.UpdValue

evt.UpdValue(adr) → 1 or 0

Runs the attribute's chain again with the value it already has, stores it and publishes it, as if it had just been written. In the chain evt.valn equals evt.valp and evt.flg carries 0x4000. An address with no @attribute, or /@*, does it for every attribute of the element. Returns 1 also when nothing matched.

evt.PubValue

evt.PubValue(adr) → 1

Sends the attribute's current value to whoever subscribes to it (MQTT, replication) without writing it and without running its chain. /@* or no attribute: all of them. Returns 1 also when nothing matched.

evt.AddElement

evt.AddElement(adr, node) → 1 or 0

Puts a new element, made with new XML, at the end of the element adr names. The new element is published like any new element: a mirror gets it at once when it has an id.

Argument Meaning
adr The parent: "id('NEW_ROWS')"
node A node taken out of its XML document with removeChild

Returns 0 when the parent is not there, when node still belongs to its document, when node is an element object of the engine (an element cannot be moved or copied this way), and when the role has no NEW right on the parent (one ALERT line).

var x = new XML("<row id=\"R7\" val=\"0\" val_typ=\"0x0308\" sta=\"0x0303\"/>", -1);
var row = x['row'];
x.removeChild(row);
evt.AddElement("id('NEW_ROWS')", row);       // 1
evt.GetValue("id('R7')/@val");               // 0: a number, found by id()

var y = new XML("<row id=\"R8\"/>", -1);
evt.AddElement("id('NEW_ROWS')", y['row']);  // 0: the node is still in y

The added element is a full engine element: its *_typ declarations, its class, its children and its chains work. Measured on 4.4.2.702, the same with and without the -1 of new XML.

evt.GetElement

evt.GetElement(adr) → an element object or undefined

The first element adr selects.

evt.GetElement("id('POWER')").val_unt   // "kW"
evt.GetElement("id('TANKS')/item").name // "one"
evt.GetElement("id('NOPE')")            // undefined

evt.DelElement

evt.DelElement(adr) → how many were deleted

Deletes every element adr selects, with their children, and publishes the deletion. An element the role may not delete (no DEL in its xdb_acl) is skipped, with one ALERT line.

evt.DelElement("id('R7')")         // 1
evt.DelElement("id('NOPE')")       // 0
evt.DelElement("id('NEW_ROWS')/*") // every child

evt.ForEach

evt.ForEach(adr, handler, prm) → 1

Calls handler once for every element adr selects.

Argument Meaning
adr Elements ("id('TANKS')/item"), or one attribute of them ("id('TANKS')/item/@val")
handler Text, "main.f(evt, idx, prm)", or a function literal whose parameters are named evt, idx, prm
prm Optional. Any value; the handler gets it as prm and what it changes in an object stays changed

In the handler evt is an event on that element: evt.atr is the attribute named in adr, or sta when none is; evt.valn is its value; relative addresses start at the element. idx counts from 0. Returning 0 (or nothing) goes on; any other value stops the walk. Elements the role may not read are skipped. ForEach returns 1 however many it visited, 0 only when the handler is missing.

function show(evt, idx, prm)
{
    prm.s = prm.s + idx + ":" + evt.id + "=" + evt.GetValue("@name") + " ";
    return 0;
}

var p = { "s": "" };
evt.ForEach("id('TANKS')/item", "main.show(evt, idx, prm)", p);
// p.s = "0:T1=one 1:T2=two 2:T3=three 3:=spare "

var q = { "n": 0 };
evt.ForEach("id('TANKS')/item", (evt, idx, prm) => { prm.n = prm.n + 1; return 0; }, q);
// q.n = 4

A literal with other parameter names ((e, i, r) => ...) fails on every element with object variable not found: the engine passes the three by name. "…/@*" visits nothing.

evt.Log

evt.Log(level, a, b, ...) → undefined

Writes one line to the document's log. The arguments after the level are joined with a space; an object or array is written as JSON, an element as <XDB_ELM>.

level Line Written when
0 PANIC always
1 ALERT xdb_log ≥ 1
2 FAIL xdb_log ≥ 2
3 ERROR xdb_log ≥ 3
4 WARN xdb_log ≥ 4 (the examples' setting)
5 NOTICE xdb_log ≥ 5
6 INFO xdb_log ≥ 6
7 DEBUG xdb_log = 7
-1 … -8 TEXT1 … TEXT8 always in the file
none TEXT4 always in the file
evt.Log(4, "tank", 2.5, { "a": 1 }, [1, 2]);   // WARN  | XDB:tank 2.5 {"a":1} [1,2]
evt.Log("no level");                           // TEXT4 | XDB:no level

A PANIC (and a FAIL) line puts the document in alarm: its sta shows EMERGENCY (ALARM for FAIL) until acknowledged — the health a log watcher reads (Keeping it running). Measured, one evt.Log(0, ..) took the document to 0x034F. A script error is a PANIC line too. Use 0 for what really is one.

new XDB_EVT

new XDB_EVT(evt) exists, but in a script it makes an empty object: no fields, and calling a method fails with object.function not found (measured). Pass evt itself.


evt.flg and the EVT.FLG constants

evt.flg is a 16-bit word. Its parts:

Bits Mask Values
0x00C0 direction EVT.FLG_PRO_MSK 0 none · EVT.FLG_PRO_INP 0x0040 came from the device · EVT.FLG_PRO_OUT 0x0080 going to the device · EVT.FLG_PRO_STA 0x00C0 a protocol state change
0x0700 source EVT.FLG_SRC_MSK EVT.FLG_SRC_RMT 0x0000 from another document · EVT.FLG_SRC_LOC 0x0100 inside the document · EVT.FLG_SRC_EVT 0x0200 a timer · EVT.FLG_SRC_UPD 0x0300 an update, not a change · EVT.FLG_SRC_FIX 0x0700
0x003F command EVT.FLG_CMD_MSK EVT.FLG_VAL_SET 0 · _MSK 1 · _XOR 2 · _ADD 3 · _MUL 4 · _UPD 5 · _ASK 6 · 7 a timer's pulse (no constant)
0x0030 class EVT.FLG_CLS_MSK EVT.FLG_CLS_VAL 0x00 · _TMR 0x10 · _CON 0x20 · _FNC 0x30 (a queued script or call)
0x0800 — the event is a copy an address write made
0x2000 — do not store: set it in a chain to veto the write
0x4000 — a forced update (UpdValue)
0x8000 — the attribute is sta

EVT.FLG_CLS_* are the top two bits of the command field.

Direction is what a pro_fnc asks. A value the device sent — a poll's answer, a subscription, the read-back after a write, a job's reply — carries FLG_PRO_INP. FLG_PRO_OUT is set by PRO.put / PRO.set on the value they hand to pro. A script's own write carries neither:

function on_rly(evt)            // pro_fnc="[main.on_rly,PRO.out,main.on_rly]"
{
    if ((evt.flg & EVT.FLG_PRO_MSK) == EVT.FLG_PRO_INP) {
        // the device says it: valn is what the pin reads now
    }
    return 0;
}

Measured on a GPIO output written from a timer: the first on_rly saw 0x0A00 (no direction), PRO.out sent the value and ended the chain, and the pin's read-back came into the same pro with 0x0140, running on_rly twice more (before and after PRO.out, which lets an input pass).


xdb: the document

xdb is the document the script belongs to. It reaches the same values as evt, with two differences: relative addresses start at the document's root element, not at an element, and it acts with the role of the script that calls it — a page's visitor through xdb is still the visitor. xdb.doc('X') gives another document as the same kind of object.

Property Gives
xdb.id The document's id: "XDB", "PLANT/S00"
xdb.sta Its sta (hex)
xdb.evt The document's own event (role 9 to read; a write through it acts with the caller's role)
xdb.eng_mode What kind of engine object it is, as bits (help: 0x1n thread, 0x2n connection, 0x4n script, 0x8n document; n = 1 server, 2 client, 4 server session, 8 client session). Measured: a document 0xB0, a <thr> 0x30, a client connection 0x72
xdb.run_mode 0x00 standalone, 0x01 load share, 0x02 standby, 0x03 hot
xdb.root The root <xdb> element as an element object: xdb.root.tid → "S01"
xdb.con The connections, by id: xdb.con['CN_WEB'] (Sessions and protocol scripts). for (k in xdb.con) lists the ids
xdb.thr The threads, by id: xdb.thr['TH_MAIN'], a thread object
xdb.mem The document's variables: xdb.mem['PRJ'], ['DB'], ['BIN'], ['ROOT'], ['TID'], and the script modules (xdb.mem['main'])

Object.keys() does not list xdb.con, xdb.thr or xdb.mem; for (k in ..) does.

xdb.doc

xdb.doc(id) → a document object, or undefined

Another document of this engine; the name is not case sensitive.

xdb.doc('plant/s00').id                                // "PLANT/S00"
xdb.doc('PLANT/S00').GetValue("id('LEVEL')/@val")       // 42.5
xdb.doc('NOPE')                                         // undefined

xdb.elm

xdb.elm(id) → an element object, or undefined

The element with that id, through the index: the fastest way to an element.

xdb.elm('POWER').val     // 0
xdb.elm('NOPE')          // undefined

xdb.GetValue

xdb.GetValue(adr) — as evt.GetValue, relative addresses from the root: xdb.GetValue("@tid") → "S01" from any function, xdb.GetValue("count(data/var)") counts the root's <data> vars.

xdb.SetValue

xdb.SetValue(adr, value) — as evt.SetValue.

xdb.MskValue

xdb.MskValue(adr, value, mask) — as evt.MskValue.

xdb.XorValue

xdb.XorValue(adr, value) — as evt.XorValue.

xdb.AddValue

xdb.AddValue(adr, value) — as evt.AddValue.

xdb.AskValue

xdb.AskValue(adr, prm) — as evt.AskValue. #JScript runs with the document's event as evt.

xdb.QueValue

xdb.QueValue(adr, value, pri, delay, syn, thr) — as evt.QueValue.

xdb.UpdValue

xdb.UpdValue(adr) — as evt.UpdValue.

xdb.PubValue

xdb.PubValue(adr) — as evt.PubValue.

xdb.AddElement

xdb.AddElement(adr, node) — as evt.AddElement.

xdb.GetElement

xdb.GetElement(adr) — as evt.GetElement.

xdb.DelElement

xdb.DelElement(adr) — as evt.DelElement.

xdb.ForEach

xdb.ForEach(adr, handler, prm) — as evt.ForEach.

xdb.Log

xdb.Log(level, a, b, ...) — as evt.Log.

xdb.normalizePath

xdb.normalizePath(text) → text

Replaces the path macros and answers with the platform's separators.

xdb.normalizePath("%DB%/x.txt")  // "C:\...\PRJ_X\db\x.txt"
xdb.normalizePath("%PRJ%")       // the project: the directory above db
xdb.normalizePath("%ROOT%")      // the directory above the project
xdb.normalizePath("%BIN%")       // the engine's directory

xdb.toID

xdb.toID(pattern, n) → text

Puts n into the digits of pattern. The digits after the letters say the width and the largest number; n wraps above it. No digits: the pattern N9999 is used.

xdb.toID('K9999', 123)   // "K0123"
xdb.toID('K99', 123)     // "K23"
xdb.toID('W0999', 7)     // "W0007"
xdb.toID('AB', 5)        // "N0005"

xdb.newID

xdb.newID(pattern [, n]) → text, or undefined

The next number of a counter kept in the file %DB%/<pattern>.txt (made at the first call), formatted as in toID. With n the counter is set to n first. The pattern may hold only letters, digits, _ and - (else undefined and one ALERT line).

xdb.newID('WR9999')       // "WR0001"
xdb.newID('WR9999')       // "WR0002"
xdb.newID('WR9999', 50)   // "WR0050"
xdb.newID('WR9999')       // "WR0051"
xdb.newID('K9999')        // "K0001"
xdb.newID('ABC')          // "ABC0001": no digits = four after the name

Before 4.4.2.703 a one-letter prefix was replaced by N ('K9999' gave "N0001") and a pattern without digits gave "ABC0" every time.

xdb.newUUID

xdb.newUUID() → text

A random (version 4) UUID: "9b141070-9198-435c-87c1-7a82ac369793".

xdb.lockID

xdb.lockID(name, ms) → 0 when the name was taken, else a code

Takes a named lock of the document, waiting up to ms ms while another holds it. 0 = taken (give it back with unlockID); not taken in time = a non-zero code (24) and one ALERT line. Measured: a second lockID of a taken name with ms = 300 came back after 301 ms with 24.

if (xdb.lockID("STOCK", 500) == 0) {
    // .. one thread at a time here ..
    xdb.unlockID("STOCK");
}

Before 4.4.2.703 it did not lock: a second lockID of a taken name returned at once with 0. Use xdb.lock with an older engine.

xdb.unlockID

xdb.unlockID(name) → 0 when the name was taken, 2147483650 when it was not

xdb.lock

xdb.lock([ms]) → 1 taken, 0 the time ran out

Takes the document's script lock, waiting ms ms (without ms: for ever). The same thread may take it again; each lock needs an unlock. Keep what runs under it short: every other script that asks waits.

xdb.unlock

xdb.unlock() → 1 released, 0 this thread did not hold it

xdb.save

xdb.save([sel [, path]]) → 1 or 0

Writes the document's values back into its XML file — every attribute written in the file, or only what sel names. Needs role 6 (Engineer) or above: from a page with a Guest visitor it returns 0 with xdb.save() refused (role 0 insufficient). What a save writes and the selector forms: Saving a document.

xdb.save()                    // 1
xdb.save("id('SPEED')/@val")  // 1: this attribute only

xdb.sync

xdb.sync([ms]) → 1, 0 or -1

Waits until every durable value written before the call is on the disk: 1 on the disk, 0 not within ms (default 3000, at most 30000) or the disk fails, -1 nothing on this node is durable (measured). Refused on a connection's thread. Values that survive a restart.

xdb.dur

xdb.dur() → an object, or undefined

The durable log's state (directory, writes, free space, documents). Role 6 or above. Measured undefined on a node with nothing durable.

xdb.ShellExecute

xdb.ShellExecute(verb, file [, params [, dir [, show]]]) → 0

Starts a program (verb "open" when empty). Role 6 or above. It always returns 0: a file that is not there is one ERROR line (ShellExecute(open,) : File not found). On Linux the file is run as a program; verb and show mean nothing there.

xdb.exitProgram

xdb.exitProgram()

Ends the engine process 100 ms after the call, with exit code 0: no clean stop of the documents. Role 6 or above; below it one ALERT line and nothing happens. Not run here.

xdb.eval

xdb.eval(text [, evt]) → the value of the last expression

Not in the help. Runs script text with the document's event (or the event given) as evt, with the caller's role: xdb.eval('evt.id') → "XDB". The same as AskValue("#JScript", text).

xdb.callFunction

xdb.callFunction(name, a, b, ...) → the function's answer

Not in the help. Calls a script function by its name with the arguments given — no evt is put in front: xdb.callFunction('main.add2', 2, 3) → 5.

xdb.sta

Reading gives the document's sta. Writing (xdb.sta = 0x0100) sets its command, later, on the document's thread: measured, xdb.doc('PLANT/S00').sta = 0x0100 stopped that document (read 0x0100 1.5 s later) and writing 0x0300 back did not start it again within 2 s. Do not switch documents from a script this way.


Element objects

evt.obj, evt.cls, xdb.elm(id), evt.GetElement(adr) and xdb.root give an element object (XDB_ELM): a handle on a live element of the document. Its attributes are its properties.

Use Does
e.val, e.name, e.val_unt Reads the attribute with its type; a class-declared one too. A missing attribute is undefined
e.val = 3.25 Writes it through the same path as SetValue: type conversion, chain, store, publish
e.newone = "hello" Creates the attribute when it is not there
delete e.x Empties the attribute (it is not removed)
JSON.stringify(e) The element's own attributes as JSON, with "xdb_elm" = the tag
var e = xdb.elm('POWER');
e.val                // 0
e.val_unt            // "kW"
e.nope               // undefined (GetValue would give "")
JSON.stringify(e)    // {"xdb_elm":"var","id":"POWER","sta_typ":322,"sta":771,"val_typ":4872,"val":0,"val_fnc":"[main.on_power]","val_unt":"kW"}
e.val = 3.25;        // POWER's val_fnc runs, POWER = 3.25

A write through an element object carries EVT.FLG_SRC_LOC, not the caller's source: written from xdb_start it is a change, not an update.

Reading another element's attribute needs the REA right in its xdb_acl (the element the event is on is always readable); a refused read looks like a missing attribute.

An element object does not walk its children. For that use addresses (evt.GetValue("id('TANKS')/item[2]/@name"), evt.ForEach) or xdb_obj.

elm.xdb_elm

e.xdb_elm → the tag name: xdb.elm('POWER').xdb_elm → "var".

elm.xdb_doc

e.xdb_doc → the document object of the script that reads it — not necessarily the element's: xdb.doc('PLANT/S00').elm('LEVEL').xdb_doc.id read from the root's script → "XDB".

elm.xdb_obj

e.xdb_obj → the element as a raw XML node, or undefined

The whole DOM, from this element: parentNode, childNodes, selectNodes, setAttribute, removeChild. Role 6 (Engineer) or above: below it undefined and one ALERT line. The DOM writes past every engine gate — no chain, no publish, no xdb_acl — so read with it; write with SetValue.

var n = xdb.elm('TANKS').xdb_obj;
n.childCount                      // 4
n[0].getAttribute('name')         // "one"
n['item'].getAttribute('id')      // "T1": the first child with that tag
n.selectNodes('item').length      // 4
xdb.elm('POWER').xdb_obj.parentNode.nodeName   // "data"

new XML: the DOM

new XML(text, -1) parses XML text into a small document of its own. It is how a script builds an element to add (evt.AddElement) and how it reads an XML answer.

new XML

new XML(text [, flags]) → an XML document

Argument Meaning
text XML text, or a file name
flags -1: the engine's own rules inside the little document — *_typ declarations give typed values, sta / pro / val / id are the engine's fields

Text that does not parse gives an XML object that is false: test if (!x).

var x = new XML("<root a=\"1\"><row id=\"R1\" v=\"5\" v_typ=\"0x0308\">t1</row><row id=\"R2\" v=\"6\"/></root>", -1);
var r = x['root'];
r.getAttribute('a')              // "1"
r['row'].v                       // 5: a number, v_typ applied
r['row'].text                    // "t1"
x.getElementById('R2').v         // "6"
r.selectNodes('row').length      // 2
x.selectNodes('count(//row)').value      // 2
x.selectNodes('sum(//row/@v)').value     // 11
var bad = new XML("<a><b/>");     // bad is false

The node members:

Member Gives
n['tag'] The first child element with that tag
n[i] The child at index i (from 0)
n.attr, n['@attr'], n.getAttribute('attr') An attribute's value; undefined when missing
n.setAttribute('attr', v) true; writes it
n.removeAttribute('attr') true; removes it
n.nodeName The tag (undefined on the document itself)
n.nodeType 1 the document, 2 an element
n.text The text inside, all levels joined
n.xml The node as XML text
n.childCount, n.childNodes The number of children; the children as a list (.length, [i])
n.firstChild, n.lastChild, n.nextSibling, n.previousSibling, n.parentNode, n.ownerDocument The neighbours
n.selectNodes(xpath) A list (.length, [i]); for count(..) sum(..) min(..) max(..) its .value
n.selectSingleNode(xpath) The first match
n.getElementById(id), n.getElementsByTagName(tag) Look-ups ('*' for every tag)
doc.createElement(tag), doc.createTextNode(text) A new detached node
n.appendChild(c), n.insertBefore(c, before), n.removeChild(c) Tree changes; each gives back the node
doc.save(file), doc.load(file), doc.loadXml(text) true / false

n.attributes and x.help give undefined.

The three steps that add an element — parse, take the node out, add it:

var x = new XML("<ac id=\"AC_4B1805\" sta=\"0x0303\" val=\"0\"/>", -1);
var ac = x['ac'];
x.removeChild(ac);                         // AddElement takes only a node with no document
evt.AddElement("id('NEW_ROWS')", ac);      // 1

Thread objects

xdb.thr['id'] and the evt.thr of an event on a <thr> give a thread object (XDB_THR).

Member Gives
t.id "TH_MAIN"
t.sta Its sta (hex). Writing it switches the thread, later: 0x0100 read 0x0101 after 1.5 s, 0x0303 brought it back
t.evt The thread's own event
t.xdb The document it belongs to
t.con The connection, for a connection's thread; undefined for a <thr>
t.ses The session, for a session's thread; undefined otherwise
t.eng_mode 0x30 a <thr>; 0x72 a client connection — see xdb.eng_mode
t.run_mode As xdb.run_mode

xdb.thr holds the <thr> threads; a connection's thread is in xdb.con (Sessions and protocol scripts).

thr.lock

t.lock([ms]) → 1 taken, 0 the time ran out

This thread's script lock, as xdb.lock: one lock per thread object, separate from the document's.

thr.unlock

t.unlock() → 1 released, 0 not held by this thread


Addresses

An address names elements and an attribute. It is XPath with the engine's own start:

Form Example Starts at
id('X')/... id('POWER')/@val the element with that id, through the index — cheap at any size
/xdb/... /xdb/data/var[1]/@id the document's root element
//tag... //var[@id='SPEED']/@val_typ every element of the document
@attr, tag/..., ../... @val_unt, ../var[2]/@id relative: see below
doc('X')/... doc('PLANT/S00')/id('LEVEL')/@val in document X

Where a relative address starts:

Who Relative to
evt in a chain or a ForEach handler the element the event is on: @val_unt is its own
evt in xdb_start, xdb_init the root element
xdb.* the root element, always
after doc('X')/ X's root element — also when X is the document you are in
// in POWER's val_fnc
evt.GetValue("@val_unt")              // "kW"
evt.GetValue("../var[2]/@id")         // "SPEED"
evt.GetValue("count(data/var)")       // 0: relative to POWER
evt.GetValue("count(/xdb/data/var)")  // 6
evt.GetValue("doc('XDB')/@tid")       // "S01": the root, not POWER

One element is read, every element is written. GetValue takes the first match, SetValue and the other writes take all of them.

Steps and predicates

Write Means Measured
item[2] the second item (from 1) id('TANKS')/item[2]/@name → "two"
item[last()] the last → "spare"
(//item)[3] the third of all of them → "three"
*, @* any element, any attribute id('TANKS')/*[1]/@id → "T1"
[@id], [not(@id)] has the attribute / has not count(//item[not(@id)]) → 1
[@val>15] = != < > <= >=, numbers compared as numbers item[@val>15]/@name → "two"
[a and b], [a or b] both, either //item[@val>=10 and @val<20]/@name → "one"
[contains(@name,'hr')], [starts-with(@name,'t')] text tests → "three", 2 items
[@name=`t%`] a pattern: % / * any run of characters, ? one character → "two"
[@sta bwand 0x0300] (value & mask) != 0; also bwor, bwnot count(//var[@sta bwand 0x0300]) → 6
[position() mod 2 = 0], [string-length(@name)=3], [name()='item'] position and text functions 2, 2, 4
following-sibling::, preceding-sibling::, .., ., // axes id('T1')/following-sibling::item → 3

A | between two paths joins their sets: count(//var|//item) → 10.

Traps, measured:

  • An unquoted hex number is a number since 4.4.2.706. count(//var[@val_typ=0x1308]) → 2, the same as [@val_typ='0x1308'] and the decimal [@val_typ=4872]; [@sta=0x0303] and [@val<0x10] compare as numbers. Before 706 an unquoted hex was read as 0: that count gave 0, [@sta=0x0303] matched nothing and [@val=0x10] picked the <var>s whose val is 0. On an older engine quote it or write it in decimal.
  • An unknown function matches nothing: [translate(@name,'a','b')='x'] → 0. There is no error. translate, local-name, boolean, lang, id() inside a predicate and $variables do not exist.
  • An unknown axis acts as child:: (//nope::item → 4), and ancestor:: is one of them: count(id('T1')/ancestor::list) → 0. Use ...
  • Count a new XPath before you trust it.

Other documents

doc('X')/ in front of an address reaches document X, wherever the address is used:

evt.GetValue("doc('PLANT/S00')/id('LEVEL')/@val")    // 42.5
evt.GetValue("doc('plant/s00')/id('LEVEL')/@val")    // 42.5: the name is not case sensitive
evt.GetValue("doc('PLANT/S00')/@sta")                // 0x0303: its root's sta
evt.GetValue("doc('PLANT/S00')/count(data/var)")     // 4
evt.GetValue("doc('NOPE')/id('X')/@val")             // undefined
evt.SetValue("doc('PLANT/S00')/id('LEVEL')/@val", 50) // 1; a val_fnc there sees evt.src_doc = "XDB"

In the other document the write's evt.flg source is FLG_SRC_RMT, and LOCAL (0x4xxx) attributes there refuse it (see evt.SetValue).

doc() comes first, the function after it. doc('PLANT/S00')/count(data/var) → 4; count(doc('PLANT/S00')/data/var) gives a wrong number (measured 2) and no error. The same for every address function.

A wildcard reaches several documents and answers a JSON list of {doc, val}, the values as text, "" where a document has no such attribute:

evt.GetValue("doc('*')/id('LEVEL')/@val")
// [{"doc":"XDB","val":""},{"doc":"PLANT/S00","val":"42.5"}]
evt.GetValue("doc('PLANT/*')/id('LEVEL')/@val")   // only those whose id starts PLANT/
evt.SetValue("doc('*')/id('LEVEL')/@val", 9)       // writes it in every one that has it

A document on another engine is reached through a PRO.rpc connection: <doc id="X" rpc_con="CN_S01"/> in the root lets every address above work unchanged, and doc('X@CN_S01') names the connection in the address itself. Such a call waits for the answer on the caller's thread; a failed one is undefined (a write 0) with one ERROR line, and inside a try it throws with the reason in e.message:

try { evt.GetValue("doc('LINE@CN_X')/id('A')/@val"); }
catch (e) { e.message }   // "doc('LINE') over 'CN_X': no PRO.rpc connection has this id or talks to this host"

Two engines has the rest.


Address functions

A function name in front of an address makes GetValue answer about a set of elements instead of one attribute. They work in every document form (doc('X')/count(...)). An unknown name gives undefined, without a log line.

count

count(xpath) → a number

How many nodes match. Not filtered by xdb_acl: a Guest visitor's count(//var) counted an element it could not read.

evt.GetValue("count(id('TANKS')/item)")   // 4
evt.GetValue("count(//nope)")             // 0

sum

sum(xpath/@attr) → a number (double)

The sum of the attribute over the matches; text that is not a number counts as 0.

evt.GetValue("sum(id('TANKS')/item/@val)")   // 34.5
evt.GetValue("sum(//nope/@val)")             // 0

min

min(xpath/@attr) → a number

evt.GetValue("min(id('TANKS')/item/@val)")   // -3
evt.GetValue("min(//nope/@val)")             // 1.79769313486232e+308

max

max(xpath/@attr) → a number

evt.GetValue("max(id('TANKS')/item/@val)")   // 20.5
evt.GetValue("max(//nope/@val)")             // -1.79769313486232e+308

min of nothing is the largest double and max of nothing its negative — not 0 and not undefined: test count first.

xml

xml(xpath) → text

The matching elements as XML, one after the other, with their children. An @attr at the end is ignored: the elements come whole. Elements the role may not read are left out, at every level.

evt.GetValue("xml(id('T1'))")
// <item id="T1" sta="0x0303" val_typ="0x0308" val="10" name="one"/>

json

json(xpath [, 'fields']) → JSON text

The matching elements as a JSON list. Each element is an object of its own attributes (not its class's) plus "xdb_elm" = its tag; numbers are numbers, hex values numbers too. With /@attr at the end, one {attr: value} per element. 'fields' keeps only those attributes. Elements the role may not read are left out; a page gets only what its visitor may read.

evt.GetValue("json(id('TANKS')/item/@val)")
// [{"val":10},{"val":20.5},{"val":-3},{"val":7}]
evt.GetValue("json(id('TANKS')/item, 'id,val')")
// [{"xdb_elm":"item","id":"T1","val":10},{"xdb_elm":"item","id":"T2","val":20.5},
//  {"xdb_elm":"item","id":"T3","val":-3},{"xdb_elm":"item","val":7}]
evt.GetValue("json(id('T1'))")
// [{"xdb_elm":"item","id":"T1","sta":771,"val_typ":776,"val":10,"name":"one"}]

This is a web front end's main read: doc('X')/json(...) over MQTT or HTTP.

stat

stat(xpath) → JSON text

The load figures of the <thr>, <con> and <xdb> elements matched: queue depth, rates, latency, skipped timers. Other elements give an empty {}. The fields are explained in Keeping it running.

evt.GetValue("stat(id('TH_MAIN'))")
// [ { "id":"TH_MAIN", "sta":"0x0303", "eng_mode":"0x30", "tmr_cnt":1, "tmr_rrb":0, "tmr_skp":0, "thr_wrk":1, ... } ]
evt.GetValue("stat(/xdb)")      // the document itself

api

api.name(a, b, ...) → the function's answer

Calls a function of the module api from an address — the way a web front end calls script (doc('X')/api.recent(10) over MQTT or HTTP). Only the api module (and rpc, below) can be called this way: main.f() in an address gives undefined.

The arguments are literals: numbers, 'text' or "text". Unquoted text arrives empty and an array arrives empty. With AskValue / SetValue the value given is added as the last argument.

The engine calls the function with four arguments in front of yours, f(evt, idx, qry, rsp, a, b, ...), and maybe more than once:

  1. first with idx = 0. A number returned means "go on" (1 forward, -1 backward, 0 stop); anything else is the answer, and it ends here.
  2. when it went on: once for every idx from 1 to qry.cnt (set qry.cnt in the first call), each returning a number again (0 stops early);
  3. then once more with idx = qry.cnt + 1; what that returns is the answer.

rsp is an empty object kept for you across the calls.

// api.js
function plain(evt, idx, qry, rsp, a)
{
    return "plain:" + a + ":" + idx;
}
function three(evt, idx, qry, rsp, a, b)
{
    if (idx == 0) { qry.cnt = 3; rsp.list = []; rsp.a = a; rsp.b = b; return 1; }
    if (idx <= qry.cnt) { rsp.list.push(idx); return 1; }
    return "done:" + JSON.stringify(rsp);
}
evt.GetValue("api.plain('x')")      // "plain:x:0"
evt.GetValue("api.plain(5)")        // "plain:5:0"
evt.GetValue("api.plain(x)")        // "plain::0": unquoted text is lost
evt.GetValue("api.three(1,'b')")    // 'done:{"list":[1,2,3],"a":1,"b":"b"}'
evt.AskValue("api.plain()", "hello") // "plain:hello:0"

Two answers that surprise:

  • An object returned comes back as the text "null". Return JSON.stringify(obj).
  • A number returned is "go on / stop", not an answer: a function that returns 0 at once gives undefined.

A function that throws gives undefined and two PANIC lines ('uncaught exception', value thrown: ...); the caller's try does not see it (measured). Only a remote call that fails throws into the caller.

rpc

rpc.name(a, b, ...) → the function's answer

The same as api., for the module rpc, but when the root has rpc_con the call runs on the other engine. Without rpc_con it runs here, as api.. Two engines covers it.

xdb

xdb(api.f, a, b, ...) → the function's answer, as JSON when it is an object

A walk over a query. f(evt, idx, qry, rsp, a, ...) is called with idx = 0 and qry = {adr: ".", cnt: 0}; it sets qry.adr to an address and returns 1. The engine counts the address's matches into qry.cnt, calls f once for each (idx 1 … qry.cnt), then once with idx = qry.cnt + 1 for the answer:

function walk(evt, idx, qry, rsp, tag)
{
    if (idx == 0) { qry.adr = "id('TANKS')/item/@val"; rsp.n = 0; rsp.tag = tag; return 1; }
    if (idx <= qry.cnt) { rsp.n = rsp.n + 1; return 1; }
    return rsp;
}
// evt.GetValue("xdb(api.walk, 'T')")  ->  {"n":4,"tag":"T"}

The per-element calls get the caller's evt, not the element's (measured: evt.id was the caller's in all four): the function can count matches but cannot read them. Use evt.ForEach to visit elements.

jsn

jsn(xpath, 'fields', api.f, prm) → JSON text

Meant as json() with a filter: api.f(evt, idx, cnt, rsp, prm) is called for each match and an element is kept when it returns non-zero. Measured, it is not usable:

  • like xdb(), the filter's evt is the caller's, so it cannot see the element;
  • without a parameter after the function it gives undefined;
  • without a filter function (jsn(//item, 'id')) every match is kept. Before 4.4.2.703 it never returned: the document's thread and the threads that wait on it stopped.

Use json(), and filter with a predicate (json(//item[@val>5])).

sql

sql(api.f, a, ...) → the function's answer

A walk over an SQL result, called like xdb(): in the first call f sets qry.con (a connection from SQL.attach) and qry.sql, then it is called once per row (qry.cols, qry.row) and once for the answer. Not measured here (it needs a database); SQL, history, files and the cluster covers SQL from script.

api(...) as a function — the form api(id('x')/@val, api.f, prm) in the help — does not exist: it gives undefined.


Special addresses

An address that starts with # is a command to the document, not a value. They work with doc('X')/#... too. Each has a fixed role floor, since there is no element whose xdb_acl could decide. A refused one returns 0 and writes one ALERT line (command '#save' refused (role 0 too low)).

Address With Role
#JScript AskValue, QueValue the caller's role governs what the script does
#PyScript QueValue as #JScript
#shell AskValue none asked: help, ver and log answer any role
#save SetValue 6 (Engineer)
#xdb_log, #log_cfg, #log_cfg_stdout SetValue 6
#dur SetValue 6
#eval SetValue 9: the engine only

An unknown # command returns 0. GetValue of a # address gives undefined.

#JScript

evt.AskValue("#JScript", text) → the value of the last expression evt.QueValue("#JScript", text, pri, delay, syn, thr) → 1

Runs script text. AskValue runs it now and answers; QueValue runs it later on a thread. In the text, evt is the caller's event (with doc('X')/#JScript: an event on X's root, and xdb is X).

evt.AskValue("#JScript", "1+2")                                    // 3
evt.AskValue("doc('PLANT/S00')/#JScript", "evt.GetValue(\"id('LEVEL')/@val\")")   // 42.5
evt.QueValue("#JScript", "main.later(evt)", THR.QUEADD_MULTI, 3000, 0, "/");

#PyScript

evt.QueValue("#PyScript", code) → 1

Hands Python code to the engine's Python thread, which runs it in its turn (eval, or exec for statements). It needs a <script language="Python"> in the project: without one, the call still returns 1 and the work is dropped with ALERT ... Python thread absent or closed, PYS event dropped. Not measured further here.

#shell

evt.AskValue("#shell", command) → text

The console's own commands: help (the engine's scope list), help <SCOPE>, ver (build, document, log file, licence and its limits), log <level> <count> (the last lines of this document's log). Anything else gives 0.

evt.AskValue("#shell", "log 4 3")   // the last three lines at WARN or above, then "-- 3 record(s), level <= 4 --"

#save

evt.SetValue("#save", 1) → 1 or 0 evt.SetValue("#save", "id('SPEED')/@val") → 1 or 0

Saves the document's values into its file, as xdb.save: 1 (or any value that is not a selector) saves every attribute written in the file, a text starting with /, [ or id( saves only what it names. doc('X')/#save saves X.

#xdb_log

evt.SetValue("#xdb_log", level) → 1

Sets the document's log level, 0–7, as xdb_log on the root does, while it runs. doc('X')/#xdb_log sets X's.

evt.SetValue("#xdb_log", 7);
evt.Log(7, "now written");   // DEBUG | XDB:now written
evt.SetValue("#xdb_log", 4);

#log_cfg

evt.SetValue("#log_cfg", cfg) → 1

Applies a log_cfg value to the running log: the stamp format (0x000F), file size (0x00F0), files kept (0x0F00) and the console copy (0x2000), as the root's log_cfg does at start. #log_cfg_stdout sets the console copy's level alone.

#dur

evt.SetValue("#dur", "drop") → 1, else 0

Forgets the document's durable values: nothing more is kept for it in this run, and the next start begins with its file. Any other value is refused with ERROR ... '#dur' takes "drop", not 'x'. Values that survive a restart.

#eval

evt.SetValue("#eval", text) → 1, 0 below role 9

Runs the {=...} expressions written in text — the placeholders the chain functions' _lnk addresses use — and keeps no result. Role 9 only, so a replication peer (role 8) can never run script with it. A script has #JScript for this.


STA: the sta word

The word

Every element has a sta: one 16-bit word in four parts. The element tree shows it as nibbles; the bits:

Bits Part Values
0x0003 run state, written by the engine 0 DISABLED · 1 STOPPED (resting) · 2 WAITING · 3 RUNNING
0x000C alarm 0x0 NORMAL · 0x4 WARNING · 0x8 ALARM · 0xC EMERGENCY
0x0030 inhibit bits STA.CFG_INHDEC 0x10 · STA.CFG_INHINC 0x20 · STA.CFG_INHALL 0x30
0x00C0 alarm handling 0x40 NEW (not acknowledged) · 0x80 suppressed · 0xC0 inhibited
0x0F00 command, written by you 0x000 DISABLE · 0x100 STOP · 0x200 PAUSE · 0x300 START
0xF000 role the cluster state and the edge / hub role (Two engines)

Run state plus alarm are the "runtime" nibble (0x000F). Test a run state with (sta & 0x0003) == 3; never compare a whole sta.

The STA scope gives names to these values:

Constant Value Constant Value
STA.DISABLED 0x0000 STA.NORMAL, STA.ALM_NRM 0x0000
STA.STARTING 0x0001 STA.WARNING, STA.ALM_WRN 0x0004
STA.WAITING 0x0002 STA.ALARM, STA.ALM_ALM 0x0008
STA.RUNNING 0x0003 STA.EMERGENCY, STA.ALM_EMR 0x000C
STA.WRN_END … STA.EMR_RUN 0x0004 … 0x000F STA.CFG_INHDEC / _INHINC / _INHALL 0x0010 / 0x0020 / 0x0030
STA.RUN_MSK 0x000F STA.CFG_NEW / _SUP / _INH 0x0040 / 0x0080 / 0x00C0
STA.ENG_MSK 0x0003 STA.CFG_MSK 0x00F0
STA.ALM_MSK 0x000C STA.CMD_MSK 0x0F00
STA.CMD_STR 0x0100 (STOP) STA.CMD_WAI 0x0200 (PAUSE)
STA.CMD_RUN 0x0300 (START)

STA.WRN_END, _STP, _WAI, _RUN, ALM_*, EMR_* are the sixteen alarm + run combinations (STA.WRN_RUN = 0x0007, STA.ALM_WAI = 0x000A). STA.CANCELED 0, STA.NEW 1, STA.STOPPED 1, STA.FINISHED 4, STA.FAILED 8 and STA.DAMAGED 12 are values for a row's own state in the low nibble of an <item>. There is no STA.START: the command values are CMD_STR (which is STOP), CMD_WAI and CMD_RUN.

STA.get_run_eng

STA.get_run_eng(sta) → the run state, 0x0000–0x0003

The functions below take a sta value — a number or hex text — and return a new value; they change nothing in the document. An element object or no argument counts as 0.

STA.get_run_eng(0x0347)      // 0x0003
STA.get_run_eng("0x0302")    // 0x0002

STA.get_run_alm

STA.get_run_alm(sta) → the alarm bits: STA.get_run_alm(0x0347) → 0x0004.

STA.get_run

STA.get_run(sta) → run state and alarm: STA.get_run(0x0347) → 0x0007.

STA.get_cmd

STA.get_cmd(sta) → the command: STA.get_cmd(0x0347) → 0x0300.

STA.set_run_eng

STA.set_run_eng(sta, eng) → sta with its run state replaced: STA.set_run_eng(0x0347, STA.WAITING) → 0x0346.

STA.set_run_alm

STA.set_run_alm(sta, alm) → sta with its alarm replaced: STA.set_run_alm(0x0347, STA.ALARM) → 0x034B.

STA.set_run

STA.set_run(sta, run) → sta with run state and alarm replaced: STA.set_run(0x0347, STA.ALM_WAI) → 0x034A. The help calls it STA.set_sta; that name does not exist.

STA.set_cmd

STA.set_cmd(sta, cmd) → sta with its command replaced

STA.set_cmd(0x0347, STA.CMD_STR)   // 0x0147: STOP
STA.set_cmd(0x0347, 0x0300)        // 0x0347
STA.set_cmd(0x0347, 3)             // 0x0047: 3 is not START, it is DISABLE

The command is a multiple of 0x0100.

Use them on evt.stan in a chain, which the engine applies when the event ends:

function over_limit(evt)       // val_fnc
{
    if (evt.valn > 90) evt.stan = STA.set_run_alm(evt.stan, STA.ALARM);
    return 0;
}

STA.upd

In: any <atr>_fnc chain, also sta_fnc. Reads: evt.stan. Changes: the element's sta, at once.

In a chain of any attribute but sta: when the alarm or run bits of evt.stan differ from the element's, writes them to the element's sta now — its sta_fnc runs — and resets evt.stan, so the functions after it see the sta as it is. Without STA.upd a changed evt.stan is applied anyway, after the chain.

In a sta_fnc chain: writes evt.valn into sta directly, without running anything, and logs NOTICE ... STA.upd: id('X')/@sta <- 0x.....

<var id="AGG2" val="0" val_typ="0x1142" val_fnc="[STA.onstalnk,STA.upd,main.agg]" .../>

main.agg sees evt.stan equal to evt.stap: the new sta is already on the element.

STA.lnk

In: sta_fnc. Reads: sta_lnk — an address; sta_lnk_idx — a nibble position. Changes: the value at sta_lnk.

When the element's run state or alarm changes, writes them (sta & 0x000F) as one nibble into the value sta_lnk names, at nibble sta_lnk_idx, with MskValue — the other nibbles are kept. Several elements can report into one value, one nibble each. sta_lnk may hold {=...} placeholders. A failed write is one NOTICE line (STA.lnk: write failed, address = ...). An older form, sta_lnk_cfg, writes chosen states as bits.

<var id="AGG1" val="0" val_typ="0x1142" val_fnc="[STA.onstalnk]" .../>
<var id="D1" sta="0x0303" sta_typ="0x142" sta_fnc="[ELM.sta,STA.lnk]"
     sta_lnk="id('AGG1')/@val" sta_lnk_idx="1"/>

D1 running normally puts 0x0030 into AGG1; D1 in ALARM (0x030B) makes it 0x00B0.

STA.onstalnk

In: <atr>_fnc of the value STA.lnk writes into. Reads: the value, nibble by nibble. Changes: evt.stan.

Makes the element's own sta from the nibbles it collects: the highest alarm of all nibbles, and WAITING when any nibble is WAITING (else RUNNING). Does nothing when the element is disabled, its alarms are inhibited (0x00C0), or the value did not change.

<var id="AGG1" val="0" val_typ="0x1142" val_fnc="[STA.onstalnk]" sta="0x0303" sta_typ="0x142"/>

Measured: AGG1 val 0x00B0 → sta 0x030B (ALARM, RUNNING); a value 0x3662 written by hand → 0x0306 (WARNING and WAITING). For alarm records from such a group, the ALM.* functions take over: Alarms, conditions and protocol chains.